Inert-Gas Thermocouple with G1/2–G1 Threaded Connection
Inert-gas thermocouple with threaded connection for atmospheric processes. Up to 60 mbar vacuum, 2 bar overpressure. For chamber and shaft furnaces.

Inert-gas thermocouple with threaded connection for atmospheric processes. Up to 60 mbar vacuum, 2 bar overpressure. For chamber and shaft furnaces.

For use in atmospheres containing inert gas, protective gas, or carbonizing gas, or in an air atmosphere with a negative pressure of 30 mbar up to a brief positive pressure of 2 bar.
| 8 | - | 01 | XX | TT | - | LLLL | PPP | A |
| 8 | Thermocouple | ||||||||||
| 01 | Gas-tight to 30 mbar and pressure-resistant up to 2 bar | ||||||||||
| XX | Number of installed thermocouples + empty test tube | ||||||||||
| TT | Thermocouple Type
| ||||||||||
| LLLL | Nominal length in mm from 0400 to 1600 | ||||||||||
| PPP | Process connection
| ||||||||||
| A | Optionally available with a calibration certificate in accordance with the current AMS 2750 / CQI-9 standard |
| 8 | - | 01 | 03 | 01 | - | 0700 | G34 |
Inert-gas thermocouple with G3/4" process thread, 2 Type S thermocouples, and a nominal length of 700 mm